Duffy | Failed Level 2

The report failed the fireplace: what each finding means and what fixes it

Price the findings

Findings that fail a prefab fireplace

Factory-built units fail when a listed part is damaged, missing or replaced with something the maker never tested. Each item below is a finding we see on Whittier reports, with the usual fix.

  • Missing or wrong termination cap: a listed cap for that pipe replaces it.
  • Rusted chase top letting water into the chase: a new cover sized to the chase, plus a check of the framing.
  • Refractory panels cracked past the maker's limit: a replacement set for that model.
  • Separated or damaged pipe sections: listed sections refitted, or the unit replaced if the model is gone.
  • Gas log set not listed for the firebox, or damper not fixed open: the log set changed or the damper secured as its maker requires.
  • Combustibles too close to the opening: the trim or mantel moved back to the listing's clearances.

Findings that fail a brick chimney

Older Whittier houses with masonry chimneys fail for different reasons. Water is behind most of them. A stack can also still carry cracks from the 1987 Whittier Narrows quake, which was centred close by, so the camera and the roof check look for old breaks as well as new ones.

  • Cracked or missing crown: patched or recast, depending on how far it has gone.
  • Open or failing flashing: reset, or replaced together with a cricket on a wide stack.
  • Cracked flue tiles: a liner, sized to the appliance.
  • No cap: a cap fitted to the flue.
  • Loose brick or open joints above the roof: repointing, or a rebuild of the top courses.

Which fixes have a fixed price

Leak repairs, crickets and gas conversions recur often enough that this site publishes a range for them. Caps are quoted after we measure. Everything else, from a crown to a liner, a damper or a chase top, depends on the measurements and the model. For those we give you a written price per item once we have seen it.

A seller can use those separate lines to decide what to fix and what to offer as a credit. A buyer can use them to ask for one or the other.

Re-inspection after the work

Once the repairs are done, we photograph each one beside the original finding. If the sale or the lender needs a clean report, a new Level 2 records the system as it now stands.

Usual fixes and their prices

Ranges cover the spread from a small single-pipe job to a large or difficult one. Your written price sits inside the range.

Water entry found and sealed
$530 to $3,150
Diverter built on the high side of a wide stack
$425 to $955
Diverter plus every flashing piece renewed
$635 to $1,600
Gas conversion in an approved firebox
$2,650 to $5,300
Fresh Level 2 once the work is done
$370
Listed or flue-sized cap, fitted
Quoted after we measure

Crowns, liners, dampers, chase tops, panels and flashing on its own have no published figure; each gets its own written price.

Failed report questions

Can a cracked prefab panel be patched instead of replaced?

Within the width the maker's manual allows, it can be left. Past that, the listed replacement panel is the only fix that keeps the unit inside its listing.

The report says the cap is not listed. It looks fine. Does it matter?

Yes. A cap the maker did not test with that pipe can upset the draft and the air gap that cools the outer pipe wall. A listed cap replaces it.

The maker of our fireplace no longer exists. What now?

Some old models have approved substitute parts sold by other companies. If none exist, the choice is between taking the fireplace out of use and replacing the unit. The written scope sets out both.

Can we fix only the safety items before close?

Many sellers do. The report ranks each finding, and our prices are per item, so the safety items can be ordered first and the rest left to the buyer or credited.

Will a gas insert fix a failed wood-burning prefab?

Only if both the fireplace and the insert are approved for each other, and the pipe is sound. Many prefab models do not allow an insert at all; we check both sets of instructions first.

Holding a failed Level 2?

Send the findings through the contact page, and we return a line-by-line price for each fix with the parts named.