Duffy

Level 2 Inspections in Whittier, With the Pipe Seen End to End

Ask About This Job

What the Job Involves

In a framed chase the parts that fail are out of sight: a pipe joint that slipped, a spacer that dropped, a firestop missing where the pipe crosses the ceiling. A Level 2 is the visit that finds them. The camera follows the pipe, and we look in the attic where it passes through and on the roof at the chase top. It costs $370, and the report goes to whoever you name.

Camera footage of each pipe joint and section
Attic pass-through and firestop seen in person
Chase top and cap checked on the roof
Captioned stills placed beside each finding
Copies sent to the people you list

Why Metal Chimneys Need the Camera

On a factory-built chimney, most of the pipe is hidden. It rises from the top of the firebox through a ceiling, through an attic or a second floor, and into a framed chase, and from the room you see only the first foot or two above the damper. That hidden length is where the trouble sits: joints that have pulled apart, a section dented when someone stacked boxes against it, rust where water from a failed chase cover ran down the outside, or an inner wall bulged by a chimney fire. On a Level 2, the camera goes through the full run, from the damper to the termination, and records it. We also climb into the attic where the pipe passes, to check the firestop spacer at the ceiling, the insulation shield where the listing calls for one, and the air gap between the pipe and the joists and rafters around it.

Those attic items matter more than they sound. The listing that lets a metal chimney pass through a wood ceiling depends on a spacer at each floor level and on the pipe keeping its stated air gap to framing and insulation. Blown-in insulation packed against the pipe, a missing shield, or a length of single wall stovepipe used to make up a short run are all common in houses that had a roof or attic redone. They are hard to see unless someone climbs up and looks, and they are the sort of fault that turns a small chimney fire into a house fire. The Level 2 report names each finding with its place in the run, says where it shows on the scan, and states what part or repair it calls for. It also tells you plainly if the chimney should sit unused until a repair is done.

When the Standard Calls for a Level 2

NFPA 211 lists the moments that call for more than a visual check: a sale or transfer of the property, a change to the appliance or the fuel, a chimney fire, and an event such as a quake or a storm that could have hurt the system. In Whittier the most common reason by far is a sale. A buyer wants to know whether the living room fireplace is usable and what it would cost to fix if it is not, and a condo buyer in La Mirada or Whittier may also need to know which parts belong to the association. The second most common reason is a planned insert or stove, since the chimney has to be judged for the new load before anyone buys equipment. Third come quake checks; the 1987 Whittier Narrows quake is still part of local memory, and owners of older brick chimneys often want to know what later shaking has done.

A Level 2 is a flat $370 for one chimney with normal access. If a house has two fireplaces on separate chimneys, each one is its own scan, and we say so when you book. The fee covers the visit, the camera work, the attic check and the written report, and it does not change because the chimney turns out to need work. Repairs are priced on a separate quote, line by line, so a buyer and a seller can agree on which items to fix and which to credit. The report goes to whoever booked the visit and to anyone they name at booking, such as both agents. From the occupant we need access to the roof and the attic hatch; in a condo, the association may also have to let us onto a shared roof, which the manager usually arranges with a phone call or a note to the building.

Four Habits on Every Duffy Chimney Sweep Job

Photos Kept

Each finding pictured for your records

Label First

Maker and model read before parts are chosen

Line by Line

A figure beside every repair item

After Shots

Finished work pictured beside the fault

More Fireplace and Chimney Work

Chimney Sweep

Soot and creosote cleared from clay flues and from the listed metal pipe inside a prefab chase, with brush heads picked for each.

Details →

Chimney Inspection

A Level 1 or Level 2 look at the venting system, firebox to termination cap, written up part by part.

Details →

Chimney Repair

Fixes to whatever carries smoke out of the house, whether a brick stack, listed metal pipe or the framed chase around it.

Details →

Fireplace Inspection

The room side of the system checked: refractory panels, screen, doors, damper, hearth and the gaps to trim and framing.

Details →

Fireplace Repair

Split panels, bent screens, failed dampers and missing trim on prefab units, fixed with parts the maker lists for that model.

Details →

Chimney Cap Installation

Termination caps for prefab pipe and fitted caps for clay flues, matched to the model or the tile size and fixed down.

Details →

Chimney Flashing Repair

Leaks where a brick stack or a framed chase meets the roof, traced and resealed with new metal and reworked laps.

Details →

Chimney Masonry Repair

Open joints, broken brick and loose upper courses on masonry stacks, repaired with mortar chosen to suit the old brick.

Details →

Chimney Rebuilds

Brick stacks that lean, crack through or pull away from the house rebuilt, or swapped for a lighter framed chase.

Details →

Fireplace Cleaning

Ash, soot and fallen debris taken out of the firebox and smoke path, with doors, screen and panels wiped down.

Details →

Gas Fireplace Cleaning

Burner, pilot hood, ember bed and glass on a sealed gas unit cleaned, with the vent ends looked at outside.

Details →

Gas Fireplace Repair

Faults on sealed and vented gas units traced with a meter, from pilot and thermopile to valve, switch and remote receiver.

Details →

Fireplace Remodel

New faces, mantels and hearths around prefab and masonry fireplaces, kept inside the maker's clearances for that model.

Details →

Fireplace Inserts

Gas and wood inserts set into an existing firebox, with a liner to the top and a face that closes off the old opening.

Details →

Pellet Stove Repair

Jams, ignition faults and sudden shutdowns on pellet stoves, traced to the failing part and repaired with the maker's spare.

Details →

Wood Stove Repair

Freestanding and hearth stoves put right: door seals, glass, baffles, firebrick and the pipe up to the chimney.

Details →

Gas Logs

Ceramic log sets fitted to the fireplace you have, with the burner type its listing allows, connected and lit.

Details →

Chimney Seismic Retrofit

Brick stacks braced, strapped or cut down and topped with a lighter section, so less heavy masonry stands above the roof.

Details →

Chimney Crown Repair

The cement top of a brick chimney sealed, patched or recast so water runs off it instead of into the flue joints.

Details →

Dryer Vent Cleaning

Lint cleared from the duct between the dryer and the outside hood, with the hood flap and the run length checked.

Details →

Chimney Liner Installation

Stainless liners for clay flues that have cracked or will serve a new insert, and listed pipe for prefab systems.

Details →

Chimney Leak Repair

Water at the ceiling, wall or firebox traced to its source, whether crown, flashing, chase cover, brick or siding.

Details →

Chimney Waterproofing

Vapor-open repellent brushed onto repaired brick, so rain stops wicking into the stack and the mortar stays drier.

Details →

Chimney Damper Repair

Dampers that stick, rattle or leak air fixed or replaced, from the throat plate in brick boxes to listed prefab assemblies.

Details →

Chimney Chase Cover

Corroded or sagging metal tops on framed chases replaced with a fitted cover that sheds water off all four sides.

Details →

Prefab fireplace guides from Duffy Chimney Sweep

Call (562) 449-0480